HitachiConcealed floor standing · RPFI
Hitachi Concealed floor standing · RPFI
Product range illustration · Source catalogue ↗

RPFI-2.0FSNQ

Hitachi · Concealed floor standing · RPFI

Rated specifications and product information, referenced directly to the manufacturer catalogue.

Cooling capacity5.6kW≈ 19,100 BTU/h
Heating capacity6.5kW
Net weight34kg
Source catalogue ↗
·
PRODUCT OVERVIEW

Hitachi RPFI-2.0FSNQ · Concealed floor standing · RPFI

Hitachi RPFI-2.0FSNQ belongs to the Concealed floor standing · RPFI range with a cooling capacity of 5.6 kW. This page provides model specifications, range illustrations and links to the source catalogue page.

Key features

01

Concealed floor installation

The unit is intended for concealed installation near floor level. Provide return/supply paths and service access as required by the installation manual.

02

Model-specific specifications

Dimensions, weight, airflow and sound reference the exact model table. Check panels and accessories separately.

TECHNICAL DATA

Technical specifications

Indoor-unit power input excludes the outdoor unit’s power consumption.

RPFI-2.0FSNQ · Rated values from the manufacturer catalogue

Rated capacity3

Rated capacity · RPFI-2.0FSNQ
Cooling capacity (kW)5.6
Converted cooling capacity (BTU/h)19,100
Heating capacity (kW)6.5

Electrical & efficiency1

Electrical & efficiency · RPFI-2.0FSNQ
Power supply220–240 V · 1~ · 50 Hz

Airflow & sound2

Airflow & sound · RPFI-2.0FSNQ
Sound pressure in catalogue order (dB(A))42/38/36
Airflow in catalogue order (m³/min)16/12.5/10.5

Dimensions & weight2

Dimensions & weight · RPFI-2.0FSNQ
Dimensions H × W × D (mm)620 × 1170 × 202
Net weight (kg)34

Refrigerant & piping4

Refrigerant & piping · RPFI-2.0FSNQ
RefrigerantR410A
Liquid pipe (mm)Ø6.35
Gas pipe (mm)Ø15.88
Drain pipe sizeVP25

BTU/h is converted from the kW rating (1 kW ≈ 3,412.142 BTU/h) and rounded to 100 BTU/h; it is not a BTU/h figure printed in the catalogue.

Cooling capacity and electrical power input are different quantities. Check catalogue test conditions when selecting equipment. Sources & notes →

Applications & layout

Select for the room layout, air distribution and installation space. Check cooling load, piping, drainage and service clearances.

Selection considerations

The English catalogue is shared by Vietnamese and English pages. Ratings follow the manufacturer’s test conditions. Confirm combinations, correction factors and accessories before design.

Overview referenceHitachi SET FREE Σ HNBQ Heat Pump (EN)Features describe the product range; model-specific ratings appear in the specification table. Applications are suggestions based on equipment type.
SOURCE DOCUMENTATION

Catalogue & notes

Model specifications reference Hitachi SET FREE Σ HNBQ Heat Pump (EN) · PDF page 24.

Combined values retain the catalogue order for voltage, frequency or fan speed. Refer to the source-page notes before use.

Rated values depend on test conditions and system combinations. Confirm optional features against the supplied configuration. The source document and edition are recorded for each model on this page.

The original English catalogue is shared by both languages; Vietnamese editorial content is translated.

Additional rating table — PDF page 26 ↗

VRF central air conditioning system design & installation

SAVA M&E Joint Stock Company specializes in designing and installing VRF central air conditioning systems for factories, buildings and luxury villas. For enquiries, please contact SAVA M&E at: https://www.savame.com/lien-he/